Configuring Communication

71

NXD/T-1200V 12" Modero® Video Wall/Flush Mount Touch Panel

8.

In some cases, you might get a Connection Details dialog (FIG. 72) requesting a VNC Server IP Address.
This is the IP Address not the IP of the Master but of the target touch panel. Depending on which method
of communication you are using, it can be found in either the:



Wired Ethernet - System Settings > IP Settings section within the IP Address field.



Wireless - Wireless Settings > IP Settings section within the IP Address field.



If you do not get this field continue to step 9.

9.

If a WebControl password was setup on the G4 WebControl page, a G4 Authentication Session password
dialog box appears on the screen within the secondary browser window.

10.

Enter the Web Control session password into the Session Password field (FIG. 71). This password was
previously entered into the Web Control Password field within the G4 Web Control page on the panel.

11.

Click OK to send the password to the panel and begin the session. A confirmation message appears
stating "Please wait, Initial screen loading.".

The secondary window then becomes populated with the same G4 page being displayed on the target G4
panel. A small circle appears within the on-screen G4 panel page and corresponds to the location of the mouse
cursor. A left-mouse click on the computer-displayed panel page equates to an actual touch on the target G4
panel page.

FIG. 72

Connection Details dialog

IP Address of touch panel
obtained from IP Settings section of
the System Settings page