Renkus-Heinz ICL-R User Manual

Page 33

Advertising
background image

IC

L

ive Users Manual - Models ICL-R & IC215S-R

33

You should know the physical dimensions of the area(s) you want to cover, so the

next logical step is to set up the audience area(s) using the Audience Area section on

the right side of the Beam Steering screen.

To simplify this step, Beam Steering provides five templates, the Standard one used

as the default starting point and four others; Small Arena, Large Arena, Open Air and

Theater. These templates are available by clicking on the Area Presets button. You

should become familiar with these templates, so we suggest you try each one of them

and then choose the one that comes closest to matching your project. Note how the

number of areas and the size of the Audience Areas change from one template to

another.

Once you have selected the template, alter the Audience Area size(s) and location(s)

to match your project’s dimensions. Notice that you can also add or delete up to a

maximum of 3 Audience Areas by using the Number field and associated drop down

arrow.

The Start field establishes the beginning point of the Audience Area relative to the “0”

point of the graph. The Start point is usually the first row of seating. Height 1 is the

height of the front of the Audience Area. It usually is “0” for the front of the first floor

area.

Length is the physical length of the Audience Area from the front edge to the rear

edge. Height 2 is the elevation (height) of the rear of the Audience Area above the “0”

plane.

The next step is to configure the steerable column(s) you will be using in your

project,i.e., to position them, define the beam(s), etc. using the IC Configuration

section on the left side of the window. See graphic to the lower right. The down arrow

associated with the Setup field allows you to select between arrays in multiple array

systems.

Now, it’s time to locate (position) the steerable column. Usually it will be on the front

wall (X = 0.00) in the beam steering Project display. If it will be placed at the front of

the stage away from the front wall, for example, move it forward by inserting its cor-

rect location. Note that after you insert a figure in the field, you need to press Enter on

your keyboard to OK the change in location.

The Y field controls the height of the column array by positioning the bottom of the

column above the Floor level (the “0” level) The default position is 6.56 feet (2

meters). The Mechanical Angle field tilts the column forward or backward (minus [-]

numbers tip it back and plus [+] numbers tilt it forward). This parameter is usually left

at 0.0 since the normal position for IC Live arrays is flat against a wall and the array’s

output digitally steered down onto the audience area.

The next step is to choose the number of Beams using the Beams field and its associ-

ated drop down menu. One of the unique features of Iconyx steerable arrays is the

ability to generate either single or multiple lobes. We’ll be discussing multiple lobes

later in this tutorial, so for now accept the default 1 beam (single lobe) configuration.

Beam Size lets you choose the Array’s opening angle which controls the sharpness of

the vertical lobe (beam). Try it out using the drop down arrow. Notice how the open-

ing angle of the array in the graphic varies as you choose different opening angles.

The High-Pass at [Hz] control allows you to insert a high pass filter into individual

beams. This new Beamware feature is used to balance the system’s low, mid and

high frequency content to improve intelligibility,

Advertising