SERVICING and TROUBLE SHOOTING (Continued)

Symptom: RHAON reports “No CobraNet Devices found.”

1. Are you trying to use a Wi-Fi connection?

You can’t use a Wi Fi connection with RHAON. Wi-Fi

doesn’t have sufficient bandwidth to handle Cobranet

and RHAON, so you will need to switch to a wired

Ethernet connection.

2. Has a private IP address been set up on the com-

puter’s Ethernet Network Interface Card (NIC)?

To check:

a. If you are running Windows 7, Windows 8 or

Vista go to Start\Control Panel\All Control Panel

Items\Network and Sharing Center\Local

Area Connection; click on Properties, then

select Internet Protocol Version 4, click on

Properties, select “Use the following IP

Address” and then enter 192.168.1.1 in the

IP address field and 255.255.255.0 in the

Subnet mask field. Leave the other fields

blank and press OK.

b. If you are running Windows XP go to

Start\\Control Panel\Control Panel and Network

Connections\LocalArea Connection; click on

Properties, then select Internet Protocol

(TCP/IP) and click on Properties, select

Use the following IP Address”. Insert 192.168.1.1

in the IP address field and 255.255.255.0

in the Subnet mask field. Leave the other

fields blank and press OK.

3. Is the correct Network Interface Card (NIC) selected in

RHAON? To check:

a. In RHAON, go to the Options pull down menu,

click on Preferences, select the General tab and

then select the correct NIC.

(Note, if the computer has more than one NIC,

make sure you select the same one you

configured in step two above.

b. Before leaving the General tab, check to make

sure RHAON is set to manage the correct IP

Range. It should be set to 192.168.1.2 to

192.168.1.100.

(Note: Although other private IP ranges can be

used we recommend the 192 168 1 address

and suggest you use it unless you have a

specific reason not to. Refer back to page 23

for details.