Recording critical Brocade DCX 8510-8 and SAN information

All commands must be entered from a CLI session (Telnet or serial) to the active CP blade unless
otherwise indicated.

Run supportShow, which includes most of the information in the following table and more. The
customer should record the location of the .txt files, which are created by the customer in this procedure
and are not called out in the supportShow results.

For detailed information about Fabric OS commands, refer to the Fabric OS Command Reference . Use
a checklist to ensure that all required information is recorded.

Critical information checklist

TABLE 15

Checked?

Data

Notes

Configuration information

Location of "config-switch.txt" file

Location of "config-miscinfo.txt" file

IP address, subnet mask

WWN for Brocade DCX 8510-8

SAN profile

Location of "SANbefor.txt" file

Notes regarding nsshow output

Notes regarding nsallshow output

Notes regarding switchshow output

Notes regarding fabricshow output

Output from supportshow command

Location of "spptshow.txt" file

Notes regarding supportshow output

Information about the new chassis

New factory serial number

New serial number (if available)

1. Open a Telnet session and log in to the Brocade DCX 8510-8 as admin. The default password is

password. Enable the logging function on your Telnet or serial console connection.

2. Back up the current configuration.

Recording critical Brocade DCX 8510-8 and SAN information

Brocade DCX 8510-8 Backbone Hardware Reference Manual

113

53-1002180-07