8510-8 supplier to order replacement parts. Both physically absent or faulty could also be the result
of the power supply not being properly seated.
FIGURE 17 Blower assembly
1. Power LED
2. Fault LED
The following table describes the LED patterns for the blower assembly.
Blower assembly LED descriptions
TABLE 8
LED purpose Color
Status
Recommended action
Power
No light (LED is off)
Blower assembly does not
have power.
Ensure that the blower assembly is
firmly seated and has power.
Steady green
Blower assembly has power.
No action required.
Fault
No light (LED is off)
Blower assembly is either
healthy or does not have
power.
Ensure that the blower assembly has
power.
Steady amber
Blower assembly has a
failure (full or partial).
Replace the blower assembly.
Slow-flashing amber (on
2 seconds, then off 2
seconds)
Blower assembly is not
seated correctly or is faulty.
Pull the unit out and reseat it. If the
LED continues to flash, replace the
unit.