Mounting the Mobility 7131

2

Brocade Mobility 7131 Installation Guide - Dependent Mode

15

53-1001567-04

CAUTION

Brocade does not recommend mounting the Mobility 7131 directly to
any suspended ceiling tile with a thickness less than 12.7mm (0.5in.)
or a suspended ceiling tile with an unsupported span greater than
660mm (26in.). Brocade strongly recommends fitting the Mobility 7131
with a safety wire suitable for supporting the weight of the device. The
safety wire should be a standard ceiling suspension cable or equivalent
steel wire between 1.59mm (.062in.) and 2.5mm (.10in.)
in diameter.

The mounting hardware required to install the Mobility 7131 above a ceiling
consists of:

Light pipe

Badge for light pipe

Decal for badge

Safety wire (strongly recommended)

Security cable (optional)

To install the Mobility 7131 above a ceiling:

1. If possible, remove the adjacent ceiling tile from its frame and place it aside.

2. If required, install a safety wire, between 1.5mm (.06in.) and 2.5mm (.10in.) in

diameter, in the ceiling space.

3. If required, install and attach a security cable to the Mobility 7131’s lock port.

4. Mark a point on the finished side of the tile where the light pipe is to be

located.

5. Create a light pipe path hole in the target position on the ceiling tile.

6. Use a drill to make a hole in the tile the approximate size of the Mobility 7131

LED light pipe.