Mounting the Mobility 7131

2

Brocade Mobility 7131 Installation Guide - Dependent Mode

17

53-1001567-04

12. Brocade recommends attaching safety wire to the Mobility 7131 safety wire tie

point or security cable (if used) to the Mobility 7131’s lock port.

13. Align the ceiling tile into its former ceiling space.

14. Cable the Mobility 7131 using either Power over Ethernet (PoE) or an approved

line cord and power supply.

For PoE installations, connect an RJ-45 CAT5e (or CAT6) Ethernet cable
between a PoE switch port and the BR7131 GE1/POE port.

For standard power adapter and line cord installations:

a. Connect a RJ-45 Ethernet cable between the network data supply (host)

and the Mobility 7131 GE1/POE or GE2 port.

b. Verify the power adapter is correctly rated according the country of

operation.

c. Connect the power supply line cord to the power adapter.

d. Attach the power adapter cable into the power connector on the Mobility

7131.

e. Attach the power supply line cord to a power supply.

CAUTION

Do not actually connect to the power source until the cabling portion of
the installation is complete.

15. Verify the behavior of the Mobility 7131 LED light pipe. For more information,

see

“LED indicators”

on page 18.

16. Place the ceiling tile back in its frame and verify it is secure.

17. The Mobility 7131 is ready to configure. For information on basic Mobility 7131

device configuration, see

“Configuring basic device settings” on page 24

.

Advertising