MESSAGE

MESSAGE MEANING

PUMP STATE

WHAT TO DO

..STOP CC......

• After 10 reset attempts

for short circuit ph-ph-gnd
of the electropump

Off

• For reset is necessary to

contact Davey technical
support

High temperature

• Water temperature above

75ºC

• Automatic reset when the

temperature falls to under
60ºC

Off

• Check that the incoming

water temperature
is within the product
specifications

• Check and restore the

correct pump priming
condition

Press.Insuff......

• High flow and very low

pressure

• Automatic reset
• (Set at the factory for 1

resetting attempt every 5
minutes if unsuccessful
the reset operation will
be attempted every 50
minutes for 24 times.
After which the system
will remain in permanently
blocked state)

Off

• Eliminate the high flow,

usually a broken pipe

• Restore correct pump

priming condition

• Check that any inline

filters are not clogged

Reset:
1 Disconnect the power

supply

2 Wait for the display to

switch off

3 Restore the power supply

No water......

• Lack of water found
• Electro-pump off
• Automatic and

programmable reset

• (Set at the factory for 5

resetting attempt every 5
minutes if unsuccessful
the reset operation will
be attempted every 50
minutes for 24 times.
After which the system
will remain in permanently
blocked state)

Off

• Check that the water is

present in the supply

• Restore correct pump

priming condition

• Check that any inline

filters are not clogged

Reset:
1 Disconnect the power

supply

2 Wait for the display to

switch off

3 Restore the power supply

ProSensor Fault.

• A pressure sensor fault

has been found

Off

• Consult the assistance

service

...continued overleaf.