Davey Speedman Compact Constant Water Pressure Systems User Manual

Page 6

Advertising
background image

6

Installations with flooded suction require a

gate or isolating valve so water supply can be
turned off for pump removal and servicing.

For Automatic Pressure Pumps

Installed with a Mains Pressure

Hot Water System

To protect your system from damage caused

by back pressure from hot water systems. You

should always have installed on the hot water

inlet an approved non-return valve.

NOTE: Always ensure hot water systems are installed in

compliance with manufacturers recommendations and in

accordance with all local regulations.

Abrasive Materials
The pumping of abrasive materials will cause damage to the pressure
system which will then not be covered by the guarantee.

Connection of Mains Scheme or Town Water

Supply to either Suction or Discharge of Pumps &

Pressure Systems

Most Water Supply

Authorities have strict

regulations regarding direct

connection of pumps to

mains water supplies. In

most cases an isolating

tank is required between

mains supply and pump.

Davey also recommend this

method. Directly applied

mains pressure can exceed pump operating pressure and damage pump.

Davey Water Products Pty Ltd can not accept responsibility for loss or

damage resulting from incorrect or unauthorised installations.