Priming and operation, Start up procedure – Davey Speedman Compact Constant Water Pressure Systems User Manual

Page 7

Advertising
background image

7

Priming and Operation

1. Remove priming plug and fill

casing and suction line (on

flooded suction, simply open

gate valve to pump). When full,

replace priming plug.

2. Ensure outlet nearest

to pump is open.

3. Ensure all valves in suction line

are open.

To Reset if Pump switches out in Pump Protection Mode

1. Switch off power.

2. Make sure pump is primed.

3. Open tap, switch on power.

4. Close tap and pump will stop.

4. Switch on power - The

status indicator will

be illuminated and

the pump will run.

See section: “Start Up

Procedure”. A full flow

of water should be

discharged from the

open tap.

5. If the pump stops with the

tap open see troubleshooting

checklist.

6. Close the open outlet or tap and

the pump should stop after a few

seconds.

Start Up Procedure

• Power the system and in 2 seconds it will display the software variant.

• Press ENTER to start system without changing any of the factory pre-sets.
• Press + only if you need to alter any of the factory pre-sets.

HCW/MT 19/02/07

**By MAC3 SpA**

Installation (+)

Start (Enter)