background image

A-4

INSTALLATION

GX 271 Chopper LPG

A-4

If growing bubbles appear, there is a leak. Re-tighten
connection or replace defective component. Retest to
make sure that there is no leak.

Leak test must be performed each time the fuel cylin-
der is replaced.

Always close the cylinder valve when the machine is
not being used.

The specification for aluminum lift truck cylinders are
shown below:

Capacity

Cylinder

Weight

Footring

LP-Gas

Volume

Empty

Outside

(LBS.)

(Cu. In.)

(LBS.)

Diameter

33.5

2219

22.5

9 3/8”

43.5

2873

25.5

9 3/8”

Note: The GX 271 LPG cannot be used with vapor draw

LP gas cylinders such as those used for recreation
vehicles, trailers, grilles, and boats.

OIL

The GX 271 is shipped with the engine crankcase filled
with SAE 10W-30 oil. Check the oil level before starting
the engine. If it is not up to the full mark on the dip stick,
add oil as required. Make certain that the oil filler cap is
tightened securely. Refer to the engine Owner’s Manual
for specific oil recommendations.

PRE-OPERATION ENGINE SERVICE

READ the engine operating and maintenance instruc-
tions supplied with this machine.

FUEL

A lift truck type coupler is provided on the supplied
fuel line for easy hand attachment to a lift truck type
LPG fuel cylinder. The fuel cylinder must meet D.O.T.
Specification 4E-240. The valve on the fuel cylinder
must be installed on the outlet marked “LIQUID”.
The engine will not develop full power if connected to
the vapor outlet.
Be certain that the cylinder valve is CLOSED before
attempting to attach the fuel supply hose coupler to the
cylinder. Connect the coupler to the fuel cylinder and
tighten by hand.

___________________________________________

After connecting the fuel supply to the supply cylinder,
open the valve on the fuel cylinder and leak test by
brushing a 50/50 soap and water solution on to the fol-
lowing connections:

• Both ends of the fuel hose where it enters the metal connector.
• The threaded fitting on the end of fuel hose attached to the GX

271 LPG fuel shut off solenoid.

• The fuel hose coupler and the connection to the cylinder valve.
• The stem of the cylinder valve and where the valve is attached

to the top of the cylinder.

• All other fittings on top of the fuel cylinder.

CAUTION

LPG

fuel can cause fire or explosion.

-

• All leak testing must be done in a well

ventilated area free from all potential
ignition sources.

• Keep sparks and flame away from machine and

LPG supply cylinder.

• Do not expose the LPG supply cylinder to temper-

atures exceeding 120°F (49°C).

• Do not weld on or near the LPG supply cylinder.
• Do not smoke or allow any potential ignition sources

near the LPG supply cylinder.

• Always be certain that the LPG supply cylinder is NOT

in the welding circuit. Do not allow either welding
cable to come in contact with the supply cylinder.

• Replace the fuel supply hose if there is excessive

abrasion, cracks or wear or if the hose is cut.

------------------------------------------------------------------------

WARNING

CAUTION

LUBRICATION SYSTEM CAPACITY

(INCLUDING FILTER)

Kohler CH20S - 2.0 Quarts (1.9 Liters)