GX 271 Chopper LPG

D-5

MAINTENANCE

D-5

BATTERY MAINTENANCE

GASES FROM BATTERY can explode.

Keep sparks, flame and cigarettes
away from battery.

To prevent EXPLOSION when:

INSTALLING A NEW BATTERY

disconnect

negative cable from old battery first and connect to
new battery last.

CONNECTING A BATTERY CHARGER

remove battery from welder by disconnecting nega-
tive cable first, then positive cable and battery
clamp. When reinstalling, connect
negative cable last. Keep well ventilated.

USING A BOOSTER

connect positive lead to

battery first then connect negative lead to negative
battery lead at engine foot.

BATTERY ACID can burn eyes and
skin.

Wear gloves and eye protection and
be careful when working near battery.

Follow instructions printed on battery.

To prevent ELECTRICAL DAMAGE when:

a) Installing a battery.
b) Using a booster.

Use correct polarity - Negative Ground.

To prevent BATTERY DISCHARGE, if you have an

ignition switch, turn it off when engine is not
running.

------------------------------------------------------------------------

The battery is a group 58, with a rating of 435 cold
cranking amps.

CLEANING THE BATTERY

Keep the battery clean by wiping it with a damp cloth
when dirty. If the terminals appear corroded, discon-
nect the battery cables and wash the terminals with an
ammonia solution or a solution of 1/4 pound (0.1113
kg) of baking soda and 1 quart (0.946 L) of water. Be
sure the battery vent plugs (if equipped) are tight so
that none of the solution enters the cells.

WARNING