Survey Menu – Conventional Mode

R-153

Resection

Survey Resection

.

The Resection screen allows you to compute an unknown occupied
position by shooting two to seven known positions.

Store Point: is the name that will be used
when the new occupied point is stored.
Instrument Height: is the height of the
instrument above the ground.
Total Resect Points to Shoot: is the number
of known positions that will be shot, from 2 to

7.
Shots per Resect Point: is the required
number of shots to shoot to each foresight when
Direct Only

is selected in the next field and is

the required number of sets when Direct and Reverse is selected in
the next field.
Sequence: is the set order when shooting each foresight. You can

select either Direct and Reverse or Direct Only.

Solve… : opens the Resection dialog box, described below, where all

of the shots are performed.

Resection – Screen Two

Resect Point: is the known point that you will
shoot.
Option: allows you to select the type of data
that is recorded when shooting the specified

foresight. You can select Distance and Angle, or
if shooting at least three foresights, you can

also select to record the Angle Only.
HR: is the length of the rod.

: Opens the Smart Target options (Page R-

Advertising