Survey Pro Reference Manual

R-284

Cut / Fill: displays the required amount of cut or fill to bring the stake
point to the elevation of the reference line at the nearest

perpendicular.

Note: If staking beyond the end points of the reference line, or if the
reference line is defined by a 2D point, no vertical data is computed.

Meas : contains the information measured by the total station during

the previous shot.

Shot : takes a shot to the prism.

< Back : returns to Screen One.

Store… : opens the Store Point dialog so you can store the last point

that was shot.

Graphic when prism is
greater than 10-feet
from the line.

Graphic when prism is
between 1-foot and
10-feet from the line.

Graphic when prism is
within 1-foot of the
line

Graphic when prism is
on the line or within the
Horizontal Distance
Tolerance specified in
the Stakeout Settings
screen (Page R-47).