2 peg test, 2 peg shots – Spectra Precision Survey Pro v4.5 Ranger Reference Manual User Manual

Page 276

Advertising
background image

Survey Pro Reference Manual

R-268

2 Peg Test

Leveling 2 Peg Test

.

The 2 Peg Test screen is used to check that the line of sight through

the level is horizontal when the bubble is properly centered.
The graphic of this screen shows the current
setup and indicates which shot you will be

shooting next with a red square. The first line

of text also indicates which shot must be taken
next.

Check H. Dist : This button appears after

shooting the initial shots to Point A. This will

measure the horizontal distance to Point B and

compare it with the distance already measured
to Point A. Come/go information is then

provided so the rod over Point B can be moved

until it equals the horizontal distance to Point A. Use of this button
is optional and the results are not used for computing the error.

Take Shot : takes the required sets of shots to the point indicated on

this screen.

2 Peg Shots

Leveling 2 Peg Test Take Shot

.

The 2 Peg Shots screen is used to perform the

required shots to whichever observation you

are shooting. The specific shots you are
prompted for depends on which rod you are

shooting and the number of sets configured in

the Level Settings screen.

The top line indicates if you are shooting the

rod over Point A or Point B, and if you are

shooting the shots for the first or second setup.

The box on the second line tells you which shot

Advertising