31

T

EST

D

ISPENSER

O

PERATION

1. Close and lock the security cabinet.

2.

Verify the cassettes are Locked (NMD only) and In Service
(multi-cassette use).

3. In

Management Functions, select Diagnostics, then

Dispenser.

4. Select

the

Test Dispense option.

5. Select either individual cassettes that are installed (“A” or “B”) or All Cassettes.

A prompt appears asking how many notes to dispense.
The default is 1.

6.

Enter the number to dispense if more than one, then press
Enter.

The Test Dispense operation will start. The Test Dispense
command instructs the dispenser to dispense at least one
note from each installed and operational cassette into
the reject vault. This test exercises the dispenser without
sending notes to the exit.

7. After completion of the Test Dispense, a prompt displays: “Test Dispense Completed Successfully -

Dispense Count , A: (# of notes), B: #.”

All Cassettes Locked

is checked.

Each cassette is checked

for Cassette In Service.

NOTE: The NMD50 cassettes
MUST be Locked and In-Service
(checked) for normal operation.