Nmd-100 – Triton FT7000XP Installation Manual User Manual

Page 37

Advertising
background image

37

I

NSTALLING

THE

NMD-100:

Note: Before proceeding, ensure the dispenser Security module and its attached cable track are out
of the way (see Pg.35, step 4).

1. Extend the slide rails out fully. With 2 persons, lift and set mechanism on the rails. Note the green lift

handle brackets attached to the dispenser have notches (2 each side) that align over the round guides
on the slide rail.

2. Reinstall the security module bracket assembly to the lift handle bracket

3. Route the dispenser data, shutter, and power cables through the side cable access hole by the front

handle.

4. Reconnect the dispenser cables mentioned above to the dispenser (reference page 35).

5. Fold any excess cables in the cable trough shown. Push the side release tabs on the slide rails and

slide the dispenser fully into the cabinet. Ensure the slide rail locking pin is engaged when completed.

Slide rail

release tab

S

ITE

P

REPARATION

/ I

NSTALLATION

*** WARNING ***

Two persons highly recommended to remove the dis-
penser from the cabinet. When removing dispenser
from cabinet, use caution not to damage the throat
extension on front of dispenser mechanism.

Advertising