ATM E

NVIRONMENTAL

P

RECAUTIONS

C

HECKLIST

TEMPERATURE/HUMIDITY

1. The ATM will operate over a range of tempera-

tures and humidity.

Generally, these param-

eters must fall within the following ranges:

Temperature (Vault/Electronics)

10°C to 40°C

50°F to 104° F

Relative Humidity

20% to 80%

(Non-Condensing)

Temperature (External)

-35°C to 50°C

-30°F to 122°F

Relative Humidity

20% to 100%

AC POWER REQUIREMENTS

2. Ensure the following AC power requirements

are met:

Current (Max)

4.0 to 6.0A @ 120V

2.0 to 4.0A @ 240V

Voltage

90V to 136V @ 50/60 Hz

198V to 257V @ 50/60 Hz

Power Consumption (Idle)

2.0A @ 115 VAC at 60 Hz

1.0A @ 230 VAC at 50 Hz

Isolated Ground. An equipment grounding conduc-
tor that is insulated from the conduit or raceway and
all other grounding points throughout its entire
length. The only points of electrical connection will
be at the duplex outlet and service panel ends of the
line.

Dedicated source. The ATMs AC power feed will be
a dedicated line to which no other electrical devices
are connected. The ATM power line will be wired for
a single “duplex”-style outlet and connected directly
to the AC service panel.

Power Consumption (Max Load)

606 Watts @ 120V

482 Watts @ 240V

RF INTERFERENCE

3. Ensure there are no devices near the terminal

that may cause RF interference, such as:

 TVs
 Security devices
 Devices with compressors

* IMPORTANT *

AC power for the terminal should
come from a dedicated source with
an isolated ground.

When installing an ATM, some general environmental and power precau-
tions need to be considered. Evaluate the location where the ATM will be
installed. To help ensure proper operation of the ATM, ensure the environ-
mental criteria listed in this checklist are met.