Van Air Systems FR-400 User Manual

Page 10

Advertising
background image

PAGE 10

SHUTDOWN

SECTION 7

Disconnect the power supply to the dryer system.

If maintenance is to be preformed on the dryer system, make sure the

dryer system is completely depressurized. Tower pressure gauges

must read 0 PSIG before removing any item on the dryer system.

STORAGE

SECTION 8

8.1 REMOVE THE PREP-40 FROM SERVICE

Shutdown the dryer system per

SECTION 7.

Close the ball valve on the afterfilter.

The pre-cooler air motor needs to be flushed to remove excessive

dirt, foreign particles, moisture and/or oil that accumulate in the air

motor during normal operation. Flushing helps to maintain proper

motor performance and extend service life.

Perform Flushing procedure, per

SECTION 8.2, when Prep-40 is

to be idle for more than 5 days, or if it is to be placed in storage.

Use only Van Air Flushing Solvent (p/n 26-7157).

DO NOT use

kerosene or ANY other combustible solvents to flush the air

motor.

8.2 FLUSHING PROCEDURE

Remove the pipe plug in the air supply line near the air motor.

Remove exhaust muffler from air motor.

Spray flushing solvent (Van Air p/n 26-7157) into air motor through tee

for 5 to 10 seconds.

Rotate motor shaft/fan, by hand, for one minute in each direction.

Reinstall the plug in the tee and cover the exhaust port with a cloth.

You must wear eye protection for this step.

Restart the motor at a low pressure (approximately 10 PSIG) and run it

until there is no trace of solvent in the exhaust air.

Listen for changes in the sound of the motor. If the motor sounds

smooth, the Prep-40 is ready for storage. If the motor does not sound

like it is running smooth, the motor will need to be serviced.

DO NOT ATTEMPT TO REMOVE OR REPAIR ANY PART OF THE

SYSTEM UNTIL IT IS COMPLETELY DEPRESSURIZED.

SERIOUS PERSONAL INJURY MAY RESULT IF THIS SAFETY

RULE IS NOT FOLLOWED.

INSPECT VESSEL, INSIDE AND OUT, REGULARLY FOR

BULGES, CORROSION, DENTS, GOUGES OR LEAKS. IF

DAMAGED, REMOVE FROM SERVICE IMMEDIATELY AND

NOTIFY YOUR CERTIFYING AUTHORITY.

WARNING

8.3 CLEAN THE EXHAUST MUFFLER

Disassemble the exhaust muffler that was removed in

STEP 8.2.

Clean the felt and reassemble the exhaust muffler.

Install the exhaust muffler on the air motor.

8.4 SET THE REGULATOR FOR THE AIR MOTOR

Set the regulator for the air motor per

FIGURE 5C.

8.5 PREPARATION FOR STORAGE

Open the ball valve on the afterfilter to completely depressurize

the Prep-40 system.

If long term storage is required, cover the inlet and outlet air

connections to prevent the accumulation of dirt and debris on the
piping.

8.6 STORAGE

Store the Prep-40 in location that is free from extreme humidity

and corrosive gasses, which can cause damage to the unit.

Shut off the air supply to the Prep-40 dryer system. Turn the dryer

system off by placing the Power Switch to the OFF position.

Manually drain the separator/prefilter by lifting the manual override

collar, on the separator/prefilter automatic drain, until no more fluid is

discharged. Manually drain the prefilter by lifting the manual override

collar, on the prefilter automatic drain, until no more fluid is discharged.

Open the ball valve on the afterfilter and completely depressurize the

dryer system.

Advertising