Questionable status register group, Psu programming manual – GW Instek PSU-Series Programming User Manual User Manual
Page 106

PSU Programming Manual
106
Questionable Status Register Group
Overview
The Questionable Status Register Group
indicates if any protection modes or limits have
been tripped.
Condition
OV
0
PTR/NTP
Event
Enable
OC
1
Not Used
2
POW
3
OT
4
Not Used
5
Not Used
6
Not Used
7
VL
8
CL
9
Not Used
10
SD
11
PL
12
Not Used
13
Not Used
14
Not Used
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Questionable Status Register
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
Logical OR
To Status Byte Register
STATus:QUEStionable:CONDition? STATus:QUEStionable:EVENt?
STATus:QUEStionable:NTRansition <NRf>
STATus:QUEStionable:NTRansition?
STATus:QUEStionable:PTRansition <NRf>
STATus:QUEStionable:PTRansition?
STATus:QUEStionable:ENABle <NRf>
STATus:QUEStionable:ENABle?
Bit Summary
Event
Bit #
Bit
Weight
OV (Over-Voltage)
Over voltage protection has been
tripped
0
1
OC (Over-Current)
Over current protection has been
tripped
1
2
POW (AC Power Off)
AC power switch is off
3