Output:external[:state, Output:delay:off, Output:mode – GW Instek PSU-Series Programming User Manual User Manual
Page 69

REMOTE CONTROL
69
:OUTPut:EXTernal[:STATe]
Set
Query
Description
Sets whether the output will be turned on or off
externally. By default this setting is turned off.
Syntax
Return Syntax
:OUTPut:EXTernal[:STATe] {<bool>|OFF|ON}
:OUTPut:EXTernal[:STATe]?
Parameter
ON | 1
External control is performed.
OFF | 0
External control is not performed.
Return parameter <bool>
Returns output status of the instrument.
:OUTPut:DELay:OFF
Set
Query
Description
Sets the Delay Time in seconds for turning the
output off. The delay is set to 0.00 by default.
Syntax
Return Syntax
:OUTPut:DELay:OFF {<NR2>| |MINimum|MAXimum}
:OUTPut:DELay:OFF?
Parameter
<NR2>
0.00~99.99 seconds, where 0=no delay.
Return parameter "0.00"
Returns the delay off time in seconds until the
output is turned off.
:OUTPut:MODE
Set
Query
Description
Sets the PSU output mode. This is the equivalent to
the F-03 (V-I Mode Slew Rate Select) settings.
Syntax
Return Syntax
:OUTPut:MODE {<NR1>|CVHS|CCHS|CVLS|CCLS}
:OUTPut:MODE?
Parameter
CVHS | 0
CV high speed priority
CCHS | 1
CC high speed priority
CVLS | 2
CV slew rate priority
CCLS | 3
CC slew rate priority
Return parameter <NR1>
Returns the output mode.