5 misc menu, 1 sequence (sequence) – GW Instek APS-1102 User Manual User Manual
Page 153

5.5 MISC Menu
APS-1102 Programmable AC/DC Power Source
5-27
5.5 MISC Menu
This menu is used to enter detailed settings for various functions. These settings can be entered regardless
of whether output is on or off.
5.5.1 Sequence (SEQUENCE)
A sequence menu is displayed. This menu is used to control sequences, set up programming, and clear
sequence memory.
a) CONTROL…(sequence control)
Select among the sequence operation control items listed below.
See “4.4.4 Control of
sequence operations”.
Table 5-19. Items in CONTROL Selection Box
Item in Selection Box
Operation
START
Starts sequence operations. Switches to Run mode.
STOP
Stops sequence operations. Switches to Idle mode.
HOLD
Holds (pauses) sequence operations. Switches to Hold mode.
BRAN0
Branches to step specified by branch step.
If the branch step is not specified, it is ignored.
BRAN1
The sequence control selection box can be selected only when output is on. If the output on/off key is
pressed while this selection box is displayed, the selection box is closed.