6.3 Command Descriptions

APS-1102 Programmable AC/DC Power Source

6-41

TST?
This returns the self test results. In this device, “0” is always returned.

Syntax:

TST?

Parameters:

None

Query

example:

TST?

Response format:

<NR1>

Response

example: 0

WAI
When all operations

※

are completed, the device is not able to execute any subsequent commands.

This is to prohibit the device from executing any subsequent command until all the operations are
completed.

Syntax:

WAI

Parameters:

None

Command example:

WAI

Response format:

None

Response example:

None

※ “Operations” means execution process of any commands in the following.

 Output mode setting

[SOURce:]MODE

 Output range setting

[SOURce:]VOLTage:RANGe

 Output relay control

OUTPut[:STATe]

 Sequence execution

PROGram[:SELected]:EXECute

 Memory recall

RCL

 Device reset

RST