GW Instek APS-1102A User Manual User Manual
Page 221

6 REMOTE INTERFACE
APS-1102A
6-37
f) STATus subsystem
STATus:OPERation:CONDition?
This returns the operation condition register (OPCR). The response ranges from 0 to 20482.
Syntax:
STATus:OPERation:CONDition?
Parameters:
None
Query example:
STAT:OPER:COND?
Response format:
<NR1>
Response example:
16384
STATus:OPERation:ENABle
This sets the operation event enable register (OPEE). The setting ranges from 0 to 20482.
Syntax:
STATus:OPERation:ENABle<NR1>
Parameters:
0 to 20482
Command example:
STAT:OPER:ENAB 16384
Query example:
STAT:OPER:COND?
Response format:
<NR1>
Response example:
16384
STATus:OPERation[:EVENt]?
This returns the operation event register (OPER) value. The response ranges from 0 to 20482.
Syntax:
STATus:OPERation[:EVENt]?
Parameters:
None
Query example:
STAT:OPER?
Response format:
<NR1>
Response example:
16384