GW Instek APS-1102A User Manual User Manual
Page 231

6 REMOTE INTERFACE
APS-1102A
6-47
RST
This resets the device to its factory settings. However, reset cannot be executed when output is on.
([1, “Invalid with output on”] error occurs.)
Syntax:
RST
Parameters:
None
Command example:
RST
Response format:
None
Response example:
None
SAV
This stores the current status information in memory. The memory storage ranges from 1 to 30.
Syntax:
SAV<NR1>
Parameters:
1 to 30
Command example:
SAV 1
Response format:
None
Response example:
None
SRE
This sets the service request enable register. The setting ranges from 0 to 178.
Syntax:
SRE<NR1>
Parameters:
0 to 178
Command example:
SRE 178
Query example:
SRE?
Response format:
<NR1>
Response example:
178
STB?
This returns the status byte register value. The response ranges from 0 to 178.
Syntax:
STB?
Parameters:
None
Query example:
STB?
Response format:
<NR1>
Response example:
2