5.5.1.6. EN50160
This page shows a table containing all values according to standard CEI EN50160.

Fig. 138: EN50160 analysis result

Column description:

Param: The percentages of the values are indicated, which must be within the

limits set in Limits. Example: Hz 100% means that the 100% of the
frequency values recorded must be within a range of 1%, -1% of the
frequency nominal value.

OK:

YES indicates that the analysis is successful, NO indicates that the

analysis is not successful.

p%@Lim: Percentage of the measured values which is within the set limits.
Min:

Minimum measured value.

Max:

Maximum measured value.

Limits: Set

reference

limits.


The following keys are active on this page:

 The up and down arrow keys move the cursor along the different quantities.

 The up and down arrow keys move the column display to the right or to the left.

 The

F1 key (or the PARAM item on the display) accesses the page showing the

settings (Fig. 139).

 The

F2 key (or the GRAPH item on the display) accesses the page showing the

histogram for the quantities in the table (Fig. 140).

 The

ESC key (or the smart icon on the display) to exit the function and go back

to the “Recording analysis” page (Fig. 125).

This page contains the global result of the EN50160 analysis, the connection condition of
the system and the parameters set before recording.