Description of hart interface, Simulation, Actual values – KROHNE OPTISONIC 7300 EN User Manual
Page 126: Information, Test/reset

9
DESCRIPTION OF HART INTERFACE
126
OPTISONIC 7300
www.krohne.com
09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en
Simulation
Process Input
<Simulation Volume Flow> / <Simulation Velocity of Sound>
Input/Output
<Simulation A> / <Simulation B> / <Simulation C> / <Simulation D>
Actual Values
Actual Values
Actual Volume Flow
Rd
/ Actual Corrected Flow
Rd, Opt
/
Actual Enthalpy Flow
Rd, Opt
/ Actual Mass Flow
Rd, Opt
/
Actual Molar Mass
Rd, Opt
/ Actual Specific Enthalpy
Rd, Opt
/
Actual Density
Rd, Opt
/ Actual Dynamic Viscosity
Rd, Opt
/
Actual Flow Speed
Rd
/ Actual Pressure
Rd, Opt
/ Actual Temperature
Rd, Opt
/
Actual Current Input A
Rd, Opt
/ Actual Current Input B
Rd, Opt
/ Operating Hours
Rd
Velocity of Sound
Actual VoS Path 1
Rd
/ Actual VoS Path 2
Rd, Opt
/ Actual VoS Path 3
Rd, Opt
Gain
Actual Gain Path 1
Rd
/ Actual Gain Path 2
Rd, Opt
/ Actual Gain Path 3
Rd, Opt
Signal to Noise Ratio
Actual SNR Path 1
Rd
/ Actual SNR Path 2
Rd, Opt
/ Actual SNR Path 3
Rd, Opt
Information
Information
C number
Rd
/
Process Input
<Sensor CPU> / <Sensor DSP> / <Sensor Driver>
<SW.REV.MS>
-
<SW.REV.UIS>
-
Electronic Revision
ER>
-
Test/Reset
Test/Reset
<List Errors> / <Reset Errors> / <Warmstart> /
<Device reset> / <Reset Configuration Changed Flag> /
<Read GDC Object>
Opt
/ <Write GDC Object>
Opt