Description of hart interface, 8 device root menu, Quick setup – KROHNE OPTISONIC 7300 EN User Manual
Page 127: Detailed setup, Detailed setup process input

DESCRIPTION OF HART INTERFACE
9
127
OPTISONIC 7300
www.krohne.com
09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en
9.11.8 Device Root Menu
Quick Setup
Quick Setup
Quick Setup
Quick Setup
Quick Setup
Language / Tag / Polling Address / <Reset Errors>
Opt
Reset Counter 1 / Reset Counter 2 / Reset Counter 3
Opt
Detailed Setup
Detailed Setup
Detailed Setup
Detailed Setup
Process Input
Calibration
Meter Size / <Zero Calibration> / GK
Filter
Minimum Limit / Maximum Limit / Flow Direction / Time Constant /
Threshold Low Flow Cutoff / Hysteresis Low Flow Cutoff
Plausibility
Error Limit / Counter Decrease / Counter Limit
Simulation
<Simulation Volume Flow> / <Simulation Velocity of Sound>
Information
<Sensor CPU> / <Sensor DSP> / <Sensor Driver> / <Calibration Date> /
<Calibration Date> / Serial Number Sensor / V Number Sensor
VoS monitor
Opt
Monitor Velocity of Sound
Monitor Settings
Monitor Settings
Monitor Settings
Monitor Settings
Opt
Opt
Opt
Opt
Matching Factor / Actual Ratio Measurement/Calibration / <New Match?> /
VoS Tolerance / Time Constant
Linearization
Linearization / Dynamic Viscosity
Opt
General
Opt
Adiabatic Index
P&T Correction
Opt
P&T Correction / <Set P&T Correction> / P&T Inputs
Opt
/ Pipe Temperature
Opt
/
Pipe Pressure
Opt
/ Density
Opt
Diagnosis Value
Diagnosis 1 / <Set Diagnosis 1> / Diagnosis 2 / <Set Diagnosis 2> / Diagnosis 3 /
<Set Diagnosis 3>
HART
Sensor s/n / <Align HART Units>
Actual Flow, Corrected Flow
Actual Flow, Corrected Flow
Actual Flow, Corrected Flow
Actual Flow, Corrected Flow
Opt
Opt
Opt
Opt
, Enthalpy Flow
Enthalpy Flow
Enthalpy Flow
Enthalpy Flow
Opt
Opt
Opt
Opt
, Mass Flow ,
, Mass Flow ,
, Mass Flow ,
, Mass Flow , …
Unit / Format / Upper Sensor Limit / Lower Sensor Limit / Minimum Span
I/O
Hardware
Terminals A / Terminals B / Terminals C / Terminals D
Current Output A/B/C
Opt
Range 0%
Cust
/ Range 100%
Cust
/ Extended Range Min
Cust
/ Extended Range Max
Cust
/
Error Current
Cust
/ Error Condition
Cust
/ Measurement
Cust
/ Range Min
Cust
/
Range Max
Cust
/ Polarity
Cust
/ Limitation Min
Cust
/ Limitation Max
Cust
/
LFC Threshold
Cust
/ LFC Hysteresis
Cust
/ Time Constant
Cust
/ Special Function
Cust
/
Threshold Range Change
Opt, Cust
/ Hysteresis Range Change
Opt, Cust
/ <Information> /
<Simulation>
Frequency Output
A/B/D
Opt
Pulse Shape
Opt, Cust
/ Pulse Width
Opt, Cust
/ 100% Pulse Rate
Opt, Cust
/ Measurement
Cust
/
Range Min
Cust
/ Range Max
Cust
/ Polarity
Cust
/ Limitation Min
Cust
/
Limitation Max
Cust
/ LFC Threshold
Cust
/ LFC Hysteresis
Cust
/ Time Constant /
Invert Signal
Cust
/ Special Function
Opt, Cust
/ Phase Shift
Opt, Cust
/ <Information> /
<Simulation>
Pulse Output A/B/D
Opt
Pulse Shape
Opt, Cust
/ Pulse Width
Opt, Cust
/ Max. Pulse Rate
Opt, Cust
/ Measurement
Cust
/
Pulse Value Unit
Rd, Cust
/ Value Per Pulse
Cust
/ Polarity
Cust
/ LFC Threshold
Cust
/
LFC Hysteresis
Cust
/ Time Constant / Invert Signal
Cust
/ Special Function
Opt, Cust
/
Phase Shift
Opt, Cust
/ <Information> / <Simulation>