Technical data – KROHNE OPTISONIC 7300 EN User Manual
Page 97

TECHNICAL DATA
8
97
OPTISONIC 7300
www.krohne.com
09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en
Passive
U
ext
≤ 32 VDC
-
f
max
in operating menu set to:
ffff
max
max
max
max
≤ 100 Hz:
100 Hz:
100 Hz:
100 Hz:
I ≤ 100 mA
R
L, max
= 47 kΩ
R
L, max
= (U
ext
- U
0
) / I
max
open:
I ≤ 0.05 mA at U
ext
= 32 VDC
closed:
U
0, max
= 0.2 V at I ≤ 10 mA
U
0, max
= 2 V at I ≤ 100 mA
f
max
in operating menu set to:
100 Hz < f
100 Hz < f
100 Hz < f
100 Hz < f
max
max
max
max
≤ 10 kHz:
10 kHz:
10 kHz:
10 kHz:
I ≤ 20 mA
R
L
≤ 10 kΩ for f ≤ 1 kHz
R
L
≤ 1 kΩ for f ≤ 10 kHz
R
L, max
= (U
ext
- U
0
) / I
max
open:
I ≤ 0.05 mA at U
ext
= 32 VDC
closed:
U
0, max
= 1.5 V at I ≤ 1mA
U
0, max
= 2.5 V at I ≤ 10 mA
U
0, max
= 5.0 V at I ≤ 20 mA
NAMUR
-
Passive to
EN 60947-5-6
open:
I
nom
= 0.6 mA
closed:
I
nom
= 3.8 mA
Passive to
EN 60947-5-6
open:
I
nom
= 0.43 mA
closed:
I
nom
= 4.5 mA
U
I
= 30 V
I
I
= 100 mA
P
I
= 1 W
C
I
= 10 nF
L
I
= 0 mH