Electrical connections, 4 alterable input/output versions, Modular ios (option) – KROHNE OPTISONIC 7300 EN User Manual

Page 30: Modbus (option)

Advertising
background image

4

ELECTRICAL CONNECTIONS

30

OPTISONIC 7300

www.krohne.com

09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en

4.5.4 Alterable input/output versions

This signal converter is available with various input/output combinations.

• The grey boxes in the tables denote unassigned or unused connection terminals.
• In the table, only the final digits of the CG no. are depicted.
• Term. = (connection) terminal

CG
no.

Connection terminals

A+

A

A-

B

B-

C

C-

D

D-

Modular IOs (option)

4 _ _

max. 2 optional modules for term. A + B

I

a

+ HART

®

active

P

a

/ S

a

active

1

8 _ _

max. 2 optional modules for term. A + B

I

p

+ HART

®

passive

P

a

/ S

a

active

1

6 _ _

max. 2 optional modules for term. A + B

I

a

+ HART

®

active

P

p

/ S

p

passive

1

B _ _

max. 2 optional modules for term. A + B

I

p

+ HART

®

passive

P

p

/ S

p

passive

1

7 _ _

max. 2 optional modules for term. A + B

I

a

+ HART

®

active

P

N

/ S

N

NAMUR

1

C _ _

max. 2 optional modules for term. A + B

I

p

+ HART

®

passive

P

N

/ S

N

NAMUR

1

Modbus (Option)

G _ _

2

max. 2 optional modules for term. A + B

Common

Sign. B

(D1)

Sign. A

(D0)

H _ _

3

max. 2 optional modules for term. A + B

Common

Sign. B

(D1)

Sign. A

(D0)

1 Changeable
2 Not activated bus terminator
3 Activated bus terminator

Advertising