3.6.3 Standpipes

Use a standpipe if:

• There is highly conductive foam in the tank.
• The liquid is very turbulent or agitated.
• There are too many other objects in the tank.
• The device is measuring a liquid (petro-chemicals) in a tank with a floating roof.

Figure 3-17: Basic installation recommendations for standpipes (stilling wells and bypass chambers)

1 Stilling well
2 Bypass chamber
3 Air circulation hole
4 Level of the liquid

CAUTION!

Installation requirements

•

The standpipe must be electrically conductive.

•

The standpipe must be straight. There must be no sudden changes in internal diameter
greater than 1 mm / 0.04

¨

.

•

The standpipe must be vertical.

•

Recommended surface roughness: <

±

0.1 mm / 0.004

¨

.

•

Stilling well only: The bottom of the stilling well must be open.

•

Adjust the probe to the center of the standpipe.

•

Make sure that there are no deposits at the bottom of the standpipe.

•

Make sure that there is liquid in the standpipe.

INFORMATION!
Standpipes are not necessary for devices with coaxial probes. But if there is a sudden change in
diameter in the standpipe, we recommend that you install a device with a coaxial probe.