KROHNE CORIMASS G-MFM 4085 EN User Manual

Page 18

Advertising
background image

18


2.2

Connection to power

–

Note information given on the instrument data plate (voltage, frequency)!

–

Electrical connection in conformity with IEC 364 or equivalent national standard.
Special regulations apply to installation in hazardous areas. Please refer to separate "Ex"
installation instructions.

– The PE protective ground conductor must be connected to the separate U-clamp

terminal in the terminal box of the signal converter.

–

Do not cross or loop the cables in the terminal box of the signal converter. Use separate
(PG or NPT) cable glands for power and output cables.

–

Ensure that the screw thread of the round cover on the terminal box is well greased at all
times.

NOTE: The grease used must be non-corrosive to aluminium; typically it must be resin- and

acid-free.

– Protect sealing ring from damage.

Outputs and
connections
see Sect. 2.3

Power and signal connections for MFC 085 K

2.3

Inputs and outputs

The table below shows the input/output connection for the converter. The exact configuration
depends on which optional output modules were fitted in the factory.

Table of input/output connections

Trm.

No.

Option 1

(Current, pulse, status

output and control input )

Option 2

*

(2 current,NGI

status output)

5

Common (-)

Common (-)

6

Current output (+)

Current output 1 (+)

4

Control input

Control input.

4.1

Pulse output

Current output 2 (+)

4.2

Status output (active)

Status output (passive)

*

The inputs/outputs share a common signal ground that is galvanically isolated from ground
(PE).

Please ensure that the information about power given on the
data plate corresponds to the locally available mains voltage.

PE

5

6

4

4.1

4.2

11

12

N L AC
–

+ DC