Martel Electronics PSC4010 User Manual

Page 31

Advertising
background image

Table 13: Frequency Measurement/Source

Range

Accuracy (% of reading ± floor)

Read

2.0CPM - 600.0CPM

0.05% ± 0.1CPM

1.0Hz - 1000.0Hz

0.05% ± 0.1Hz

1.00KHz - 10.00KHz

0.05% ± 0.01KHz

Source

2.0CPM - 600.0CPM

0.05%

1.0Hz - 1000.0Hz

0.05%

1.00KHz - 10.00KHz

0.250%

Input voltage amplitude range on frequency is 1V to 20V zero based square wave only.Output amplitude is
adjustable from 1V to 20V, and is a square wave with 50% duty cycle.For output frequency, a slight negative
offset of approximately -0.1V is present to assure zero crossing.

29

Advertising