NOSHOK 2100 Series Field Upgradeable Dual Input Process Indicator User Manual

Page 33

Advertising
background image

33

5-tOt

Totalizer (Integrator) Parameters

8-Out

Analog Output Parameters

7-SrL

Serial Communication Parameters

DISPLAY

PARAMETER

FACTORY

SETTING

USER SETTING

asIN
dECPt

TOTALIZER ASSIGNMENT

TOTALIZER DECIMAL POINT

A-rEL

0.000

tbASE

TOTALIZER TIME BASE

Min

SCFAC

TOTALIZER SCALE FACTOR

1.000

Locut

TOTALIZER LOW CUT VALUE

-19.999

P-uP

TOTALIZER POWER-UP RESET

NO

DISPLAY

PARAMETER

FACTORY

SETTING

USER SETTING

tYPE
bAUd

COMMUNICATIONS TYPE

BAUD RATE

MbAS

38400

dAtA

DATA BIT

8

PAr

PARITY BIT

NO

dELAY

Addr

TRANSMIT DELAY

METER ADDRESS

0.010

247

INP b

INP A

Opt

Abrv

INPUT A VALUE

PRINT OPTIONS

ABBREVIATED PRINTING

NO

NO

NO

NO

CALC

CALCULATION

NO

tot

PRINT TOTAL VALUE

NO

HILO

PRINT MAX & MIN VALUES

NO

SPNt

NO

PRINT SETPOINT VALUES

PARAMETER

FACTORY

SETTING

USER SETTING

tYPE

4-20

ASIN

ANALOG ASSIGNMENT

0

AN-LO

ANALOG LOW SCALE VALUE

0

AN-HI

ANALOG HIGH SCALE VALUE

10000

udt

ANALOG UPDATE TIME

0.0

ANALOG TYPE

DISPLAY

9-FCS

Factory Setting Parameters

*Select alternate list to program these values.

4-SEC

Secondary Function Parameters

FACTORY

SETTING

USER SETTING

PARAMETER

DISPLAY

1.0

OFF

0.010

CALCULATION FILTER SETTING

UNITS LABEL BACKLIGHT

C fLt

b-LIt

C bNd

0.001

0.000

1

A-rEL

CALCULATION ROUNDING

CALCULATION DECIMAL POINT

DISPLAY UPDATE TIME

MAX CAPTURE ASSIGNMENT

C rnd

C dP

dSP-t

HI-AS

A-rEL

1.000

c+A+b

1.0

0.000

MIN CAPTURE ASSIGNMENT

CALCULATION CONSTANT VALUE

CALCULATION FUNCTION

MIN CAPTURE DELAY TIME

INPUT B OFFSET VALUE

LO-AS

conSt

CFunc

LO-t

OFS-b

1.0

0.000

MAX CAPTURE DELAY TIME

INPUT A OFFSET VALUE

HI-t

OFS-A

CALCULATION FILTER BAND

3

DISPLAY INTENSITY LEVEL

d-LEV

USER SETTING

FACTORY

SETTING

PARAMETER

DISPLAY

2-FNC

User Input and Function Key Parameters

DISPLAY

PARAMETER

USER SETTING

FACTORY

SETTING

USr-1

USER INPUT 1

NO

USr-2

USER INPUT 2

NO

F1

FUNCTION KEY 1

NO

F2

FUNCTION KEY 2

NO

rSt

RESET KEY

NO

Sc-F1

2nd FUNCTION KEY 1

NO

Sc-F2

2nd FUNCTION KEY 2

NO

3-LOC

Display and Program Lockout Parameters

CALCULATION ASSIGNMENT

TOTAL DISPLAY LOCKOUT

INPUT B ASSIGNMENT

MIN DISPLAY LOCKOUT

0

SECURITY CODE

COdE

LOC

LOC

SETPOINT 2 ACCESS

SETPOINT 4 ACCESS

SP-2

SP-4

LOC

LOC

SETPOINT 1 ACCESS

SETPOINT 3 ACCESS

SP-1

SP-3

dSP-C

LOC

CALC

tOt

dSP-b

LOC

dSP-a

LOC

INPUT A ASSIGNMENT

MAX DISPLAY LOCKOUT

INP b

LO

INP A

HI

FACTORY

SETTING

USER SETTING

PARAMETER

DISPLAY

INPUT B VALUE

6-SPt

Setpoint (Alarm) Parameters

DISPLAY

PARAMETER

FACTORY

SETTING

USER SETTING

FACTORY

SETTING

SP-1

ACt-n

SETPOINT ACTION

NO

SP-n

SETPOINT VALUE (main)

100

HYS-n

SETPOINT HYSTERESIS

2

tON-n

ON TIME DELAY

0.0

tOF-n

OFF TIME DELAY

0.0

out-n

OUTPUT LOGIC

nor

rSt-n

RESET ACTION

AUto

Stb-n

STANDBY OPERATION

NO

Lit-n

SETPOINT ANNUNCIATORS

nor

USER SETTING

SP-2

NO

SETPOINT VALUE (alternate) *

100

200

2

0.0

0.0

nor

AUto

NO

nor

200

FACTORY

SETTING

USER SETTING

FACTORY

SETTING

SP-3

NO

300

2

0.0

0.0

nor

AUto

NO

nor

USER SETTING

SP-4

NO

300

400

2

0.0

0.0

nor

AUto

NO

nor

400

SPSEL

SELECT SETPOINT

NO

ASN-n

SETPOINT ASSIGNMENT

NONE

NO

NONE

NO

NONE

NO

NONE

Shaded area available when communications type is

rLc

.

Advertising