NSi Industries DG280A-24 User Manual

Page 13

Advertising
background image

11

screen to show OFF . DST may be activated again by

pressing DEL . Press ENTER to save changes . To change

the from the standard DST month/week/day setting

press HOUR and refer to step 4 .1 .

6 . CYCLE MODE: To change duty cycle timing, press

either the HOUR, MIN, or SEC keys . Press ENTER to

save changes .

7 . SCH MODE: To change schedule, press ENTER to

advance to desired event . Press HOUR, MIN, EVENT

to modify time settings . Press DEL to delete . Press

ENTER after each modification to save changes .

8 . SKIP MODE: Press D/ON, D/OFF and DAY to

modify existing settings . Press ENTER to save

changes .

NOTES:
1 . Unit has a look back feature . Press the EVENT key

once (or twice for two circuit units) to activate current

schedule then EVENT key again to return to the

time (run) screen . Unit will automatically pick up the last

schedule .

2 . To clear date and time only and provide unit with

a soft reboot, press and release the reset button that is

recessed under the small hole to right side of LCD

screen .

3 . To clear all memory, while in the RUN mode, press

ENTER, display will show:

Use the EVENT key to display:

Advertising