Fail-safe network – Revo RESPTZ37-1/HSC/HSW User Manual User Manual

Page 10

Advertising
background image

REVO America

www.revoamerica.com

RESPTZ37-SERIES

8

TIP

Set up all of your devices now to ensure that you only have one selected as the last
device. Record the device, which is the last device for future reference.

Fail-Safe Network

The camera may be controlled by both REVO and non-REVO devices such and keyboard
controllers or DVRs. Using these devices, you can set up the camera and all of the functions. The
ideal way to do this is using a REVO keyboard. It provides the easiest way to take full advantage
of the camera’s capabilities. It also provides a fail-safe network by protecting the camera if any of
the following conditions occur:

• When the RS-485 circuit is open (Break)
• When the RS-485 circuit is shorted
• When RS-485 circuit is damaged

When a non-REVO device is used, there also may be some problems with the communication
between the camera and controller device. To compensate for this, set DIP switch SW2 poles 1
and 2 (Figure 2) to ON in the camera closest to the controller device. Typical connections are
shown in Figure 3.

See Setting Camera Protocol and Video Standard for additional instructions on using non-REVO
keyboard controllers or DVRs.

SW2

1

2

ON

PULL-UP

PULL-DOWN

OFF

NONE