West Control Solutions KS 800 Profibus Interface Manual User Manual

Page 13

Advertising
background image

Rem. B1 Alarm_x

MSB

LSB

D7

D6

D5

D4

D3

D2

D1

D0

Bit no.

Name

Allocation

Status ‘0’

Status ‘1’

D0

Lim HH

Alarm HH

off

on

D1

Lim H

Alarm H

off

on

D2

Lim L

Alarm L

off

on

D3

Lim LL

Alarm LL

off

on

D4

Fail

Alarm Sensor Fail

no

yes

D5

HCAl

Heating current alarm

off

on

D6

LeckAl

Leakage current alarm

off

on

D7

do1_8Al

Alarm OUT1 ... 8

off

on

Rem. C Status_x

MSB

LSB

D7

D6

D5

D4

D3

D2

D1

D0

Bit no.

Name

Allocation

Status ‘0’

Status ‘1’

D0

w/W2

w/W2 switch-over

w

W2

D1

We/w

External/internal switch-over

external

internal

D2

w/Wanf

Start-up set-point switch-over

w

Wanf

D3

Orun

Optimization active

no

yes

D4

A/M

Automatic/manual switch-over

auto

manual

D5

Coff

Controller switched off

no

yes

D6

Y1

Switching output 1

off

on

D7

Y2

Switching output 2

off

on

Rem. D Unit_Contrl I

MSB

LSB

D31 D30 D29

...

...

D2

D1

D0

Bit no.

Name

Allocation

Status ‘0’

Status ‘1’

D0

OUT1

Forcing of output OUT1

off

on

D1

OUT2

Forcing of output OUT2

off

on

D2

OUT3

Forcing of output OUT3

off

on

D3

OUT4

Forcing of output OUT4

off

on

D4

OUT5

Forcing of output OUT5

off

on

D5

OUT6

Forcing of output OUT6

off

on

D6

OUT7

Forcing of output OUT7

off

on

D7

OUT8

Forcing of output OUT8

off

on

D8

OUT9

Forcing of output OUT9

off

on

D9

OUT10

Forcing of output OUT10

off

on

D10

OUT11

Forcing of output OUT11

off

on

D11

OUT12

Forcing of output OUT12

off

on

D12

OUT13

Forcing of output OUT13

off

on

D13

OUT14

Forcing of output OUT14

off

on

D14

OUT15

Forcing of output OUT15

off

on

D15

OUT16

Forcing of output OUT16

off

on

Process data

13

9499 040 50511