Lan installation, Power requirements, Ac power – Badger Meter GALAXY User Manual

Page 15: Customer-supplied dc power, Ac power customer-supplied dc power

Advertising
background image

Installation & Operation Manual

LAN Installation

Figure 16: LAN Connections

Install a NEMA (4x if outdoors) enclosure according to state and local electrical codes, installed so as to be accessible by

authorized personnel from ground level .
Minimum Enclosure size: 12” x 10” x 6” .
Your NEMA enclosure should contain a hole large enough to pass the GALAXY power / communication cable through . The

hole must be sealed with the appropriate NEMA 4x approved cord or conduit sealing device .
Outlets and enclosure are not included .
* The surge suppressor connects in-line between the serial cable and the LAN converter box . The ground wire connects to an

earth ground .

POWER REQUIREMENTS

AC Power

Badger Meter provides a DC to AC power supply which plugs into a standard three-prong 110V AC outlet . If you are powering

the Gateway directly via DC power, please refer to the DC power information .

Customer-Supplied DC Power

The Badger Meter GALAXY Gateway GPRS receiver requires 12 – 18V DC power source capable of delivering 200 mA

continuously and up to 500 mA peak at 12V DC . If connecting to a voltage supply of less than 15V DC the power /

communication cable length is limited to 100 feet .