External power source connections, Maintenance, Fcc requirements – Badger Meter GALAXY User Manual

Page 16

Advertising
background image

GALAXY® Gateway Receiver 3.0 Fixed Network

The Badger Meter GALAXY Gateway Wi-Fi receiver requires 12 – 18V DC power source capable of delivering 200 mA

continuously and up to 360 mA peak at 12V DC . If connecting to a voltage supply of less than 15V DC the power /

communication cable length is limited to 100 feet .

External Power Source Connections

Wire Color

External DC Power Source

Drain (no insulation)

Negative (–)

Black

Negative (–)

Brown

Not Used/Cut off at outer Jacket

Red

Positive (+)

Light Blue

Not Used/Cut off a outer Jacket

NOTE:

N

Unused wires should be cut off at the outer jacket .

MAINTENANCE

Please visually inspected the Gateway Receiver 3 .0 unit, its cabling and mounting hardware along with any additional

installation hardware on an annual basis to be sure that the unit remains in the condition of its original installation .

FCC REQUIREMENTS

The Badger Meter GALAXY Gateway Receiver 3 .0 complies with Part 90 of the Federal Communications Commission Rules . An

FCC license is required for operation of the GALAXY system .

Page 16

January 2013

Advertising