Installation Manual

ELECTRICTL CONNECTIONS

M12 Connector Tssembly

The M12 connector assembly is required for all power source configurations except LAN with PoE .

NOTE:

N

Use only approved Badger Meter power cable, 100-foot (66233-015) or 300-foot (66233-017), for

this assembly .

Tools and Materials

Included with gateway:

M12 plug, 8-conductor connector (66525-002)

Badger Meter power cable, 100-foot or 300-foot, with 308 in-line connector end

308 in-line connector anti-tamper collar

Customer-supplied:

Coax stripper (customer-supplied)

Wire stripper for 22 AWG wires (customer-supplied)

Precision slotted screwdriver with blade size of 2 .0 millimeter (0 .079 inch) (customer-supplied)

M12 Plug Connector Part Names

Figure 22: M12 plug connector parts

1 . Push the connector parts onto the power cable in the following order: pressure nut, clamping cage, cable seal, sleeve

with O-ring and finally, the coupling sleeve .

2 . Strip the cable outer jacket to a maximum length of 1 .1 inches .

Figure 23: Stripped cable wires

3 . Shorten the foil shield flush with the outer jacket .

Female Insert

Coupling Sleeve

Sleeve

w/O-ring

Cable

Seal

Clamping

Cage

Pressure Nut

Page 23