ORION® Fixed Network (SE) II Network Gateway Transceiver

4 . Attach the metal housing to the

RJ45 receptacle on the gateway:

Remove the RJ45 receptacle

bayonet lock cap from the

gateway by turning the cap

1/4 turn counter clockwise .

NOTE:

N

The RJ45 receptacle cap

should be saved so it can be

replaced if the Ethernet cable

is removed later .

Place the metal housing on

the RJ45 receptacle and turn

it until you feel the metal

housing align with the keys

on the RJ45 receptacle

(Figure 33) .

Once aligned, tighten the

outer sleeve on the metal

housing 1/4 turn clockwise .

NOTE:

N

The metal housing fits on

the RJ45 receptacle correctly

when it is aligned with the

keys on the RJ45 receptacle .

Figure 32: Bayonet lock cap

Figure 33: Remove bayonet lock cap

5 . Attach the half insulators to

the RJ45 modular plug on the

Ethernet cable connector:

Hold down the plug latch and

slide one of the half insulators

over the latch . Make sure the

half insulator prong is aligned

next to the plug latch as

shown in Figure 35 .

Figure 34: Plug latch

Figure 35: Half insulator over latch

Slide the other half insulator

over the other side of the

latch while holding the half

insulator you just attached,

again making sure the

prong is aligned next to the

plug latch .

Squeeze both insulators

together to connect . You

will hear a “click” when the

connection is made . The plug

with both half insulators is

shown in Figure 36 .

Figure 36: Half insulators connected

RJ45 Receptacle Bayonet

Lock Cap

Page 28