Installation Manual

6 . Insert the Ethernet cable connector into

the RJ45 receptacle . Push the connector

in firmly .

The plug latch of the connector fits into

the recessed key section of the RJ45

receptacle . A close-up view from the front

is shown in Figure 37 .

An audible click confirms a

complete connection .

NOTE:

N

Once assembled, RJ45 plugs cannot be

disassembled from the metal housing

without a special tool (67163-001) .

Figure 37: RJ45 receptacle close up

7 . Screw the cable gland onto the metal housing on the RJ45 receptacle and tighten the cable gland nut .

See Figures 38 and 39 . Recommended: Use a torque wrench to tighten to 30…45 inch-pounds.

8 . Tighten the dome nut on the cable gland (Figure 39) . Recommended: Use a torque wrench to tighten to 20 inch-pounds.

NOTE:

N

The gray seal inside the dome nut must be in firm contact with the Ethernet cable . As the dome nut is tightened,

the seal should fill the open end of the dome nut without popping out the front and should be in firm contact

with the outer jacket of the Ethernet cable . See Figures 40 and 41 .

Figure 38: Screw cable gland onto metal housing

Figure 39: Tighten the cable gland nut

Figure 40: Gray seal before dome nut is tightened

Figure 41: Gray seal after dome nut is tightened

Assembly is complete . For additional information, refer to

http://www.rjfield.com/Ethernet_connectors_rjf_en.htm .