ORION® Fixed Network (SE) II Network Gateway Transceiver

4 . Strip the ends of the six (6) colored wires to a length of 1/8 inch . Twist the conductors on each wire .
5 . Shorten the drain/bare wire (no insulation) to 11/16 inch .
6 . Loosen each screw (about 2…3 turns) on the female insert and attach the wires to the female insert using the chart

below . Retighten each screw after the wire has been connected .

BE CAREFUL NOT TO BACK THE SCREWS OUT TOO FAR. THE SCREWS ARE SMALL AND CAN EASILY BE LOST IF THEY

ARE DROPPED.

Function

Wire

Female insert connector

Female Insert Diagram - Top View

Female Insert Photo - Top View

V DC+

Red

1

V DC–

Brown

2

V DC–

Black

3

RS232

White*

4

RS232

Green*

5

Not used

Not

used

6

V DC+

Blue

7

V DC–

Drain**

8 (Center)

* Used with the serial programming harness (66529-002)

** Used with shielded cable only

NOTE:

N

For additional information about DC power source, see

"Absolute Requirements" on page 20

.

7 . Assemble the female insert to the coupling sleeve by aligning the female insert tab slot with the notch in the

coupling sleeve .

Figure 24: Slot alignment

Female Insert

Tab Slot

Coupling Sleeve Insert

Notch

Slot

Brown

Red

Black

Blue

White

Not

Used

Green

Drain