ORION® Fixed Network (SE) II Network Gateway Transceiver

2 . If there is a connection, the backhaul antenna bracket and antenna can remain connected to the gateway . Remote

installation is not required for the backhaul antenna .

If there is no connection, remove the backhaul antenna bracket from the gateway .

There are two locknuts holding the backhaul antenna mounting bracket on the backplate . Remove those to

separate the antenna bracket and backhaul antenna from the backplate .

3 . Move the antenna bracket with the backhaul antenna to the nearest outdoor location and test again .

4 . If there is a connection, mount the backhaul

antenna bracket .

If there is still no connection to the gateway, move

the antenna bracket and backhaul antenna to the

highest location available, up to 100 feet away from

the gateway enclosure . Additional cable may be

required .

5 . Mount the backhaul antenna bracket using either

V-block mounting hardware or Band-IT banding,

depending on the structure .

NOTE:

N

The antenna can be inverted as shown in

Figure 58 for easier mounting . For complete

information, see

"Backhaul Antenna Bracket"

on page 13 .

Figure 58: Inverted backhaul antenna bracket

6 . Prepare the cable and connector per manufacturer's instructions and connect to the Type N male connector at the

bottom of the backhaul antenna .

NOTE:

N

A lightning arrestor is recommended for all remote antenna installations . See

"Lightning Arrestors" on page

26

for additional information .

7 . Collect the required VSWR readings

after the

antenna is installed in its final location . Record the

information on the form provided by Badger Meter .

See

"Required Antenna Tests" on page 36 .

8 . Connect the backhaul antenna to the Type N female

connector on the gateway enclosure (marked

”Backhaul Antenna Only”) .

The backhaul antenna cable can be connected

directly to the enclosure .

If needed, a 3-foot coaxial cable with Type N male

connectors (67628-001) can be used to transition

from the backhaul antenna connector to the Type N

female connector on the enclosure .

Figure 59: Backhaul Antenna connector

9 . Complete the ORION Fixed Network II Gateway Installation Form and send the completed form to Badger Meter with

any attachments . The three-page form starts on page 43 .
The remote backhaul antenna connection is complete .