Screen Layout for Other Reports

For all reports except History, the following descriptions apply

The middle section of the Gateway Reading Reports screen is blank

The right side of the Gateway Reading Reports screen displays the report, which includes the individual account

information and the Meter Readings table

The Show History button in the tool bar can be used to run a History report for an account

Two text boxes are displayed in the bottom tool bar next to the Close button The left is blank The right contains the

number of records returned for the report selected

Status

When a report is run, status indicators display across the top of the report The box will be checked if the status was reported

by the endpoint at the time of the read In Preview mode, status is displayed as a single letter as shown in the Preview Status

column in the table below

Gateway Reading

Reports Status

Preview

Status

Description

Program

O

Endpoint received a program parameter change For example, it was reprogrammed via IR

Device

D

Device condition Endpoint reports an encoder error for ENC For ELCD, conditions are

indicated in the extended status as shown below

E-Series

HR-E LCD

Empty Pipe

Reverse Flow

Encoder Removal

Reverse Flow

Temp Limit

Leak

Temp Limit

Leak

Encoder Life

Encoder Programmed

Encoder Life

Encoder Programmed

No Usage

Sensor Error

No Usage

Magnetic Tamper

Tamper

T

Endpoint reports a tamper condition

Reverse

R

Endpoint reports the encoder measured flow in the reverse direction

No Use

U

Endpoint reports no usage

Leak

L

Endpoint reports a potential leak condition

Low Batt

A

Endpoint reports that its estimated battery life is low

Primary

Y

The Primary indicator is only checked for the endpoint current reads Current reads are

collected when the

Current Reads

schedule runs

Mobile

M

Endpoint read collected via mobile device

Usage Report Status

In addition to the status indicators listed above, the Usage report also has three additional columns—Max, Min, Usage—to

show the maximum, minimum and current usage as reported by the endpoint

Source

Except for the Usage report, the Source of the read is shown in the last column of the reports The following options

can display

Fixed: Current or Fixed: Historical which indicates the reading is from a gateway

Fixed: Current displays when the

Current Reads

schedule is run Fixed: Historical displays when the

Historical Reads

schedule is run

Mobile: Current or Mobile: Historical

which

indicates the reading is from a mobile collection device

Mobile Source indicators only display for customers with both fixed and mobile reading systems

OTE:

N

If the read Source is Mobile (Current or Historical), the number in the Gateway # column on the report is shown as “-1 “