Reports

Endpoint Alarms

Report

Report

Status

Description

Potential Leak (Water) Leak

RTR: Endpoints with an RTR look for 1 hour of non-usage in 24 hours
ENC: Endpoints with an ADE or HRE look for 2 hours of non-usage in 24 hours
ELCD: Endpoints with an HR E-LCD encoder report 24 hours without one 15-minute

interval of no flow

Cut Cable or Magnetic

Tamper

Tamper

Endpoint(s) reporting a tamper condition when the wire between the register and the

endpoint is cut or shorted With gas meters, a tamper occurs when the presence of an

external magnetic field interferes with the ability of the gas endpoint to accurately

record consumption

No Usage

No Use

Endpoint(s) reporting no usage No usage conditions occur when there is no flow over

a 30-day time frame

Reverse Flow

(ENC, GAS, ELCD)

Reverse

Endpoint(s) reporting that the encoder has reverse direction measured flow, causing

the current reading to be lower than the previous recorded reading

Encoder Error (ENC)

Encoder

Device condition Endpoint(s) reporting an encoder error Error conditions occur when

the encoder exhibits a temporary or permanent failure to extract the current reading

Cover Removal (GAS)

Cover

Device condition

Endpoint(s) reporting error due to meter cover or partial cover

removal

Device Condition

(ELCD)

Device

The specific conditions indicated in the extended status See “Device“ under

"Status"

on page 29.

Low Battery

Low Batt

Endpoint(s) reporting estimated remaining battery life is low

Mobile Mode Indicator Mobile

Endpoint(s) reporting in mobile mode

Programmed

Parameter Change

Program

Endpoint received a program parameter change Example, it was reprogrammed via IR

Priority of Alarms: Low Battery, Tamper, Reverse Flow, Leak, No Usage, Encoder Error (ENC)/Device Condition (ELCD)

Endpoint alarms are based on the most current reading within the time period selected

NOTE:

N

Encoder error descriptions differ depending on the encoder type Refer to the HR-E LCD Encoder Installation and

Programming Manual and E-Series Ultrasonic Meters User Manual, available at

www.badgermeter.com

, for more

information about HR E LCD and E-Series status indicators and clearing alarms

Reading Reports

Last Read

The most current meter reading within the time period selected

No Read

The most current meter reading for endpoints that have not reported within the time period selected

Usage

The most current meter reading, the lowest meter reading, and the difference between them within the

time period selected Use the section titled "Set Options for Report Preview" at the bottom left to select

records to show when previewing the report

Not Advancing

The most current meter reading for endpoints where the meter reading did not change within the time

period selected

Notifications

Endpoints with notifications set on Endpoint Settings or Account Records screens If Alarm Notifications

are not set on either screen, the report is blank

Leak Logger

Refers to a report from the Permalog® acoustic leak detection device

History

All endpoints that have reported meter readings within the time period selected, along with the

individual meter readings collected within that time