Certificate of calibration – Badger Meter Cox Precision Turbine Meters User Manual

Page 12

Advertising
background image

www.badgermeter.com

15555 North 79th Place • Scottsdale, AZ 85260 • Phone: (480) 948 -3789 • Fax: (480) 948 -3610 •

[email protected]

Doc Nbr: CRF-002 Rev: F

Report #:CX35874 - X14892

Page 1 of 1

Certificate

of Calibration

Customer Name:

HONG KONG EVERBLOOMING INTL CO LTD

Report #

CX35874 - X14892

Customer Address:

Sooner Air Freight Int’l Ltd Unit 7,Corp Square, 8 Lam Lok Street KLN BAY Hong Kong

Customer PO #

13EB0205COX

Model #

NRPC 12

Cal Date:

2/21/2013

Serial #

X14892

Customer Re-Cal Date:

Signal:

PULSE (Collect Raw Data)

Lab Temp:

72.1 Deg F

Calibration Procedure:

FDP-002

Lab Relative Humidity:

27.3%

Calibration Tech:

Luis

Fluid Specifications:

MIL-C-7024 T2

Specific Gravity:

0.76

Temperature (F):

80

Viscosity (CSTKS):

1.12

Notes, Adjustments & Repairs

Calibration Results (Initial Calibration)

Test Point # Frequency Flow Rate Roshko # Strouhal # Meter Temp Viscosity Density Flow Rate

Hz

GPM

Hz/cstk

pul/gal

Deg. F

cStks

g/cc

LPM

1

10.5941

0.23290

10.1597

2729.48

72.223

1.0428

0.7662

0.88161

2

10.5995

0.23292

10.1649

2730.62

72.223

1.0428

0.7662

0.88169

3

16.4760

0.35749

15.8004

2765.43

72.224

1.0428

0.7666

1.35326

4

16.4773

0.35751

15.8017

2765.55

72.224

1.0428

0.7666

1.35331

5

23.0864

0.49779

22.1398

2782.83

72.229

1.0428

0.7665

1.88435

6

23.0878

0.49790

22.1411

2782.42

72.229

1.0428

0.7665

1.88474

7

31.8261

0.68334

30.5241

2794.65

72.239

1.0427

0.7665

2.58671

8

31.8233

0.68336

30.5214

2794.30

72.244

1.0427

0.7665

2.58681

9

45.9753

0.98154

44.0817

2810.58

72.207

1.0430

0.7665

3.71553

10

45.9764

0.98158

44.0913

2810.53

72.224

1.0428

0.7665

3.71569

11

65.0253

1.38527

62.2155

2816.58

71.909

1.0452

0.7665

5.24383

12

65.0929

1.38719

62.2802

2815.61

71.909

1.0452

0.7665

5.25109

13

92.3185

1.97035

88.2532

2811.37

71.782

1.0461

0.7665

7.4586

14

92.7150

1.97801

88.7088

2812.52

71.909

1.0452

0.7665

7.4876

15

126.727

2.71355

121.228

2802.25

71.876

1.0454

0.7665

10.2719

16

126.986

2.71960

121.429

2801.72

71.829

1.0458

0.7665

10.2948

17

172.915

3.72060

165.032

2788.63

71.567

1.0478

0.7668

14.084

18

173.020

3.72232

165.100

2789.03

71.539

1.0480

0.7668

14.0905

19

249.704

5.39233

238.001

2778.54

71.382

1.0492

0.7668

20.4122

20

250.070

5.39867

238.304

2779.35

71.347

1.0494

0.7668

20.4362

21

353.158

7.64305

335.772

2772.47

71.032

1.0518

0.7669

28.9321

22

353.580

7.65082

336.141

2772.96

71.016

1.0519

0.7669

28.9615

23

487.881

10.5643

462.716

2770.99

70.694

1.0544

0.7669

39.9901

24

488.960

10.5857

464.180

2771.49

70.824

1.0534

0.7669

40.0714

25

724.643

15.6740

686.287

2773.97

70.499

1.0559

0.7669

59.3325

26

725.055

15.6826

685.830

2774.01

70.321

1.0572

0.7669

59.3651

27

986.019

21.3207

976.576

2775.36

76.755

1.0098

0.7669

80.7077

28

993.053

21.4722

982.275

2775.43

76.571

1.0111

0.7668

81.281

29

1406.85

30.3943

1390.06

2777.71

76.414

1.0122

0.7668

115.055

30

1412.22

30.5055

1393.71

2778.13

76.245

1.0134

0.7668

115.476

Standards Used in Calibration

The instrument referenced above was calibrated using standards traceable to the National Institute of Standards and Technology. Calibration reports for references

maintained by Badger Meter, Inc. are available upon request to the customer of this calibration report. The volumetric flow rates reported are within a best

uncertainty of +/- .037% of reading (Represents an expanded uncertainty using a coverage factor, k = 2, at an approximate level of confidence of 95%) and applies to

calibration equipment only and does not apply to the UUT ( Unit Under Test).

Badger Meter, Inc. Flow Dynamics calibration services are accredited by NVLAP (Lab Code 200668-0) to ISO/IEC 17025:2005 (NIST Handbook 150) and are

compliant to ANSI/NCSLZ540-1-1994; Part 1. This certificate is not an endorsement by NVLAP, NIST or an agency of the federal government.

The results reported relate only to the item(s) calibrated as described above. This report may not be reproduced, except in full, without the written approval of

Badger Meter, Inc..

I certify the accuracy of this Calibration Report:

Andrew Yee

Calibration Engineer

Name

Title

Signature

Standard #

Description

Serial #

ReCal Date

FDI-180

30 GPM Liquid Prover

NA

8/12/2013

Figure 6: Calibration certification

Precision Meters, Turbine Flow Meters

Page 12

May 2014