Tri-clamp end fitting, High pressure end fitting, Tri-clamp end fitting high pressure end fitting – Badger Meter Cox Precision Turbine Meters User Manual

Page 16

Advertising
background image

Tri-Clamp End Fitting

A

2X TRI-CLAMP END FITTINGS

(PER ASME BPE)

C

B

FLOW METER

A

B

C

ASME BPE END FITTING DASH NUMBER

CX08-4SAXXCB 3.56

3.2

1.50

1/2"

8-4

CX08-6SAXXCB 3.56

3.2

1.50

1/2"

8-6

CX08SAXXCB

3.56

3.3

1.50

1/2"

8

CX10SAXXCB

3.56

3.3

1.77

1-1/4"

10

CX12SAXXCB

3.56

3.4

1.77

1-1/4"

12

CX16SAXXCB

3.56

3.5

1.99

1-1/2"

16

CX20SAXXCB

4.59

3.6

2.17

1-1/2"

20

CX24SAXXCB

4.59

3.8

2.38

1-1/2"

24

CX32SAXXCB

6.06

4.0

3.18

2"

32

Figure 11: Tri-clamp end fitting

Size

End Fitting

in. (mm)

A

in. (mm)

B (RF)

in. (mm)

B (MAG)

in. (mm)

C

in. (mm)

Clamp Size

in. (mm)

8-4

0 .50 (12 .70)

3 .56 (90 .42)

3 .20 (81 .28)

2 .70 (68 .58)

1 .50 (38 .10)

0 .75(19 .05)

8-6

0 .50 (12 .70)

3 .56 (90 .42)

3 .20 (81 .28)

2 .70 (68 .58)

1 .50 (38 .10)

8

0 .50 (12 .70)

3 .56 (90 .42)

3 .30 (83 .82)

2 .80 (71 .12)

1 .50 (38 .10)

10

1 .25 (31 .75)

3 .56 (90 .42)

3 .30 (83 .82)

2 .80 (71 .12)

1 .77 (44 .96)

1 .50 (38 .10)

12

1 .25 (31 .75)

3 .56 (90 .42)

3 .40 (86 .36)

2 .90 (73 .66)

1 .77 (44 .96)

16

1 .50 (31 .80)

3 .56 (90 .42)

3 .50 (88 .90)

3 .00 (76 .20)

1 .99 (50 .55)

20

1 .50 (31 .80)

4 .59 (116 .6)

3 .60 (91 .44)

3 .10 (78 .74)

2 .17 (55 .12)

24

1 .50 (31 .80)

4 .59 (116 .6)

3 .80 (96 .52)

3 .30 (83 .82)

2 .38 (60 .45)

32

2 .00 (50 .80)

6 .06 (153 .9)

4 .00 (101 .6)

3 .50 (88 .90)

3 .18 (80 .77)

2 .00 (50 .80)

Table 8: Tri-clamp end fitting dimensions

High Pressure End Fitting

A

B

HEX BODY

SQUARE BODY

A

B

BODY

SQUARE

SQUARE

SQUARE

SQUARE

SQUARE

HEX

HEX

HEX

HEX

(Compliant with AS4375)

Figure 12: High pressure end fitting

Size

End Fitting

in. (mm)

A

in. (mm)

B (RF)

in. (mm)

B (MAG)

in. (mm)

C

in. (mm)

8-4

0 .50 (12 .70)

3 .25 (82 .55)

3 .20 (81 .28)

2 .70 (68 .58)

1 .12 (28 .45) Square body

8-6

0 .50 (12 .70)

3 .25 (82 .55)

3 .20 (81 .28)

2 .70 (68 .58)

1 .12 (28 .45) Square body

8

0 .50 (12 .70)

3 .50 (88 .90)

3 .30 (83 .82)

2 .80 (71 .12)

1 .12 (28 .45) Square body

10

0 .625(15 .88)

4 .00 (101 .6)

3 .30 (83 .82)

2 .80 (71 .12)

1 .25 (31 .75) Square body

12

0 .75 (19 .05)

4 .50 (114 .3)

3 .40 (86 .36)

2 .90 (73 .66)

1 .50 (38 .10) Square body

16

1 .00 (25 .40)

4 .75 (120 .7)

3 .50 (88 .90)

3 .00 (76 .20)

1 .63 (41 .40) Hex body

20

1 .25 (31 .75)

5 .50 (139 .7)

3 .60 (91 .44)

3 .10 (78 .74)

1 .88 (47 .75) Hex body

24

1 .50 (38 .10)

6 .00 (152 .4)

3 .80 (96 .52)

3 .30 (83 .82)

2 .25 (57 .15) Hex body

32

2 .00 (50 .80)

7 .00 (177 .8)

4 .00 (101 .6)

3 .50 (88 .90)

2 .75 (69 .85) Hex body

Table 9: High pressure end fitting dimensions.

Precision Meters, Turbine Flow Meters

Page 16

May 2014

Advertising