Battery

The "LBat" indicator displays when the battery is approaching end of life When the indicator is illuminated, the 2/3AA, 3 0

VDC lithium battery is drained to 10% of its total capacity and should be changed Normal battery life is four years "Normal"

assumes operating conditions of an ambient temperature of 25° C (77° F) and a throughput of 60,000 liters (15,850 gallons,

63,400 quarts, 126,800 pints (US))

OTEE:

N

A 2/3AA, 3 6 VDC battery may also be used as a replacement

Figure 4E: Low Battery Indicator

Checksum

To display the firmware checksum:

1 Press and hold the RESET button for three seconds
2 To return to normal display, release the RESET button

Display Scale Factor

To display the Scale Factor:

1 At the same time, press and hold the TOTAL and RESET buttons for two seconds to display the programmed

scale factor

2 To return to the normal display, release both buttons