SAFETY

Explosion and Fire Hazards

Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in an

explosion or fire and cause serious injury

Be sure the fluid system is properly grounded See your pump instruction manual for details

If there is static sparking or if you feel an electric shock while using the meter, stop dispensing immediately Identify

and correct the problem before continuing

Provide fresh air ventilation This will avoid the buildup of fumes from the fluid being dispensed

Do not smoke while dispensing flammable fluids

Keep the dispensing area free of debris including solvents, rags and spilled gasoline

Meter Hazards

Equipment misuse can cause the meter to rupture or malfunction and cause serious injury

This equipment is for professional use only

Read all instructions, tags and labels before operating the equipment

Use the equipment only for its intended purpose

Do NOT modify or alter the equipment

Do NOT leave equipment unattended while dispensing

Check equipment daily Repair or replace worn or damaged parts immediately

Do NOT exceed the maximum working pressure level of the lowest rated system component

Use only extensions and nozzles that are designed for use with this equipment

Use only fluids and solvents that are compatible with the equipment Read all fluid and solvent

manufacturer’s warnings

Tighten all fluid connections before operating this equipment

Do NOT stop or deflect leaks with hands, body, gloves or rags

Do NOT dispense towards any person or any part of the body

Do NOT place hands or fingers over the end of or into the dispense valve

Comply with all local, state and federal fire, electrical and safety regulations

Use of this product in a manner other than specified in this manual may result in impaired operation or damage

to equipment

These meters are designed to dispense a wide range of chemicals Consult the factory for chemical compatibility

Industrial Oval Gear Meter and Register

Page 6

May 2013

Advertising